The revised edition of the "IEE On-Site Guide" reflects updates included in the latest edition of the "IEE Wiring Regulations" (17th edition) 2008. "The On-Site Guide" is intended to enable the competent electrician to deal with small installations (up to 100 A, 3-phase). It provides essential information in a convenient, easy-to-use form, avoiding the need for detailed calculations. It includes simple circuit calculations. Essential for all electricians, electrical contractors and their managers, installation designers, and students in further education and professional training.
| ISBN | 0863418546 | | DEWEY edition | DC22 | | ISBN13 | 9780863418549 (What's this?) | | Pages | 183 | | Publisher | Institution of Engineering and Technology | | Volumes | 001 | | Imprint | Institution of Engineering and Technology | | Published in | Stevenage | | Format | Spiral / Comb Bound | | Previous ISBN | 9780863413742 | | Publication date | 01 Sep 2008 | | Height (mm) | 210 | | Library of Congress | TK3271 | | Width (mm) | 148 | | DEWEY | 621.31924 | | Academic level | Professional / Scholarly, Technical/vocational |
|
| |
| | | Cooperating organisations | | 6 | | | | Preface | | 7 | | | | Foreword | | 9 | | Sect. 1 | | Introduction | | 11 | | Sect. 2 | | The service position | | 15 | | Sect. 3 | | Protection | | 19 | | Sect. 4 | | Earthing and bonding | | 27 | | Sect. 5 | | Isolation and switching | | 33 | | Sect. 6 | | Labelling | | 37 | | Sect. 7 | | Final circuits | | 43 | | Sect. 8 | | Locations containing a bath or shower | | 69 | | Sect. 9 | | Inspection and testing | | 73 | | Sect. 10 | | Guidance on initial testing of installations | | 77 | | Sect. 11 | | Operation of RCDs | | 91 | | App. 1 | | Maximum demand and diversity | | 95 | | App. 2 | | Maximum permissible measured earth fault loop impedance | | 99 | | App. 3 | | Selection of types of cable and flexible cord for particular uses and external influences | | 105 | | App. 4 | | Methods of support for cables, conductors and wiring systems | | 111 | | App. 5 | | Cable capacities of conduit and trunking | | 117 | | App. 6 | | Current-carrying capacities and voltage drop for copper conductors | | 123 | | App. 7 | | Certification and reporting | | 135 | | App. 8 | | Standard circuit arrangements for household and similar installations | | 157 | | App. 9 | | Resistance of copper and aluminium conductors | | 165 | | App. 10 | | Selection of devices for isolation and switching | | 169 | | App. 11 | | Identification of conductors | | 171 | | | | Index | | 177 |
|
|
|
|
|